Pre-configured Stroma® Enterprise Data Repository™
-
Three Database System support: MS SQL Server, DB2,
Oracle
-
Install/restore DVD’s
-
Operating System: Windows Server 2003 Enterprise
Edition
-
Dual channel Ultra320 SCSI controller, 2 internal
disks on one channel, 1 internal disk on a second channel
-
External Ultra320 SCSI port
-
2 x 10/100/1000Base TX LAN (auto speed sensing, RJ
45 connector)
-
Telnet and web console via 10/100Base TX management
LAN (RJ 45 connector)
-
1 x general purpose RS 232 serial port
-
Factory integration of CPUs, memory, disk drives,
removable media, and I/O cards
-
HP L1506" 15" Flt Panel Monitor
-
USB keyboard and USB scroll mouse
-
Field Rack kit (needed for field integration into
19" wide cabinets at customer location). Includes rails and bezel
-
Pedestal server mounting kit (for stand-alone, vertical
system mounting)
-
One year HP warranty with
next business day on site
|
System |
| Processors |
1.6
GHz Intel Itanium 2 processor |
| Cache |
6
MB |
| Floating
point |
Yes |
|
Coprocessor included
|
| System
Memory |
8 GB
|
| Internal
Disks |
3 x 73GB
15K RPM Ultra320 SCSI Low Profile Hot Plug Disk |
|
DVD+RW drive
|
|
Integrated I/O |
| |
Ultra320
SCSI–LVD |
2
channels |
10/100/1000Base-T
(RJ-45 connector) |
2
port |
RS-232
serial ports
(general purpose) |
2 |
10/100Base-T
management port
(RJ-45 connector) |
Yes |
| VGA
graphics |
2D/3D
PCI Graphic Adapter |
| USB |
4
|
I/O Buses and Slots |
|
Total
PCI-X/PCI Slots |
4 |
|
All four slots are 133-MHz, 64-bit slots on dedicated PCI-X buses
|
Electrical Characteristics |
|
AC
Input power |
100-240V
50/60 Hz |
| Hot
swap Power supplies |
1
included, 2nd for N+1 |
| Redundant
AC power inputs |
1
included, 2nd for N+1 |
| Current
requirements at 230V |
4
A (shared across inputs) |
| Typical
maximum power dissipation |
600
Watts |
| Theoretical
maximum power dissipation |
1,350
Watts |
| kW
rating for UPS loading |
1.3 |
| Typical
Heat dissipation |
1,945
BTUs/hour |
|
Maximum Heat dissipation
|
4,375
BTUs/hour |
Site Preparation |
|
Rack
depth (inches/mm) |
26.8
in (680 mm) |
| Rack
width (inches/mm) |
19 in
(482 mm) |
| Rack
height (EIA/inches/mm) |
2U/
3.4 in (86 mm) |
| Pedestal
depth (inches/mm) |
26.5
in (672 mm) |
| Pedestal
width (inches/mm) |
11.7
in (297 mm) |
| Pedestal
height (inches/mm) |
19.5
in (494 mm) |
| Weight
(lb/kg) |
Maximum 56 lb (25 kg)
|
Environmental Characteristics |
| |
Acoustics
(operator/bystander) at 77° F (25° C) |
<6.8
Bels LwA |
Operating
Temperature
(up to 5000 ft/1524 m)* |
41°
to 95° F (5° to 35° C) |
| Non-operating
Temperature |
5°
to 35° F (-40° to 70° C) |
| Maximum
rate of temperature change |
10°
C/hour |
| Operating
relative humidity |
15%
to 80% RH non-condensing |
| Non-operating
relative humidity |
8%
to 85% non-condensing |
| Operating
altitude above sea level |
10,000
ft (3,000 m) maximum |
| Non-operating
altitude above sea level |
15,000
ft (4,600 m) maximum |
|
*NOTE: Maximum operating temperature range up to 5000 feet. For
higher altitudes, de rate the maximum temperature by 2°C/1000
feet above 5000 feet.
|
Regulatory
Compliance |
|
RMN |
RSVLA-0403 |
| Electromagnetic
interference |
Complies
with FCC Rules and Regulations, Part 15 as a Class A digital device.
Manufacturer's Declaration to EN55022 Level A, VCCI Registered, Class
A, Korea RLL, CCC, BMSI Taiwan |
| Safety |
CSA
NRTL Certified, EN 60950-1 |
|